{"title":"Ochranné relé proti přepětí, podpětí","description":"\u003cp\u003e\u003c\/p\u003e","products":[{"product_id":"monitoring-protection-three-phase-relay-for-overvoltage-undervoltage-control","title":"Relè di monitoraggio\/protezione trifase per il controllo di sovratensione e sottotensione","description":"\u003ch2 data-start=\"62\" data-end=\"119\"\u003e\u003cstrong data-start=\"65\" data-end=\"119\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eGKM-11 - Relè monofase di sovratensione e sottotensione, TENSE\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"121\" data-end=\"143\"\u003e\u003cstrong data-start=\"125\" data-end=\"143\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDescrizione del prodotto\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"144\" data-end=\"380\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè GKM-11 è utilizzato per proteggere le apparecchiature sensibili da sovratensioni e sottotensioni nei sistemi di distribuzione monofase. Quando il limite superiore o inferiore di tensione impostato viene superato, il relè apre il contatto di uscita e scollega il carico, evitando danni alle apparecchiature.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"382\" data-end=\"405\"\u003e\u003cstrong data-start=\"386\" data-end=\"405\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFunzione e funzionamento\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"406\" data-end=\"706\"\u003e\n\u003cli data-start=\"406\" data-end=\"555\"\u003e\n\u003cp data-start=\"408\" data-end=\"429\"\u003e\u003cstrong data-start=\"408\" data-end=\"427\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndicazione di stato:\u003c\/font\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"432\" data-end=\"555\"\u003e\n\u003cli data-start=\"432\" data-end=\"462\"\u003e\n\u003cp data-start=\"434\" data-end=\"462\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eStato normale - LED verde\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"465\" data-end=\"509\"\u003e\n\u003cp data-start=\"467\" data-end=\"509\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eErrore di alta tensione - LED rosso \"HV\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"512\" data-end=\"555\"\u003e\n\u003cp data-start=\"514\" data-end=\"555\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eErrore di bassa tensione - LED rosso \"LV\"\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"556\" data-end=\"652\"\u003e\n\u003cp data-start=\"558\" data-end=\"652\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"558\" data-end=\"583\"\u003eProtezione regolabile:\u003c\/strong\u003e limiti di tensione superiore e inferiore, ritardo di commutazione (DT) e tempo di ripristino (RT)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"653\" data-end=\"706\"\u003e\n\u003cp data-start=\"655\" data-end=\"706\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"655\" data-end=\"672\"\u003eContatto relè:\u003c\/strong\u003e 5 A \/ 250 V CA (carico resistivo)\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"708\" data-end=\"731\"\u003e\u003cstrong data-start=\"712\" data-end=\"731\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDati tecnici\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"732\" data-end=\"1061\"\u003e\n\u003cli data-start=\"732\" data-end=\"771\"\u003e\n\u003cp data-start=\"734\" data-end=\"771\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTensione di esercizio: 220 V CA, 50\/60 Hz\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"772\" data-end=\"809\"\u003e\n\u003cp data-start=\"774\" data-end=\"809\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCampo di alta tensione: 230-300 V\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"810\" data-end=\"846\"\u003e\n\u003cp data-start=\"812\" data-end=\"846\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCampo di bassa tensione: 150-210 V\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"847\" data-end=\"883\"\u003e\n\u003cp data-start=\"849\" data-end=\"883\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTempo di ritardo e reset: 0,5-20 s\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"884\" data-end=\"903\"\u003e\n\u003cp data-start=\"886\" data-end=\"903\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eConsumo di energia: \u0026lt;6 VA\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"904\" data-end=\"942\"\u003e\n\u003cp data-start=\"906\" data-end=\"942\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTemperatura di funzionamento: da -20 °C a +55 °C\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"943\" data-end=\"964\"\u003e\n\u003cp data-start=\"945\" data-end=\"964\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMontaggio: guida DIN\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"965\" data-end=\"985\"\u003e\n\u003cp data-start=\"967\" data-end=\"985\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePeso: 0,1 kg\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"986\" data-end=\"1017\"\u003e\n\u003cp data-start=\"988\" data-end=\"1017\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSezione massima del cavo: 2,5 mm²\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1018\" data-end=\"1061\"\u003e\n\u003cp data-start=\"1020\" data-end=\"1061\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAltitudine massima di installazione: 2000 m\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1063\" data-end=\"1078\"\u003e\u003cstrong data-start=\"1067\" data-end=\"1078\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplicazione\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1079\" data-end=\"1184\"\u003e\n\u003cli data-start=\"1079\" data-end=\"1114\"\u003e\n\u003cp data-start=\"1081\" data-end=\"1114\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDistribuzione e quadri elettrici monofase\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1115\" data-end=\"1184\"\u003e\n\u003cp data-start=\"1117\" data-end=\"1184\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApparecchiature elettriche sensibili, elettrodomestici, macchinari industriali\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52989458317644,"sku":"GKM-11","price":39.68,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0941\/8391\/5852\/files\/20317c23ee072c0847607f7b28061c2c.png?v=1753394964"},{"product_id":"monitoring-protection-three-phase-relay-for-control-of-overvoltage-undervoltage-asymmetry-sequence","title":"Relè di monitoraggio\/protezione trifase per il controllo di sovratensione, sottotensione, sequenza di asimmetrie","description":"\u003cdiv\u003e\n\u003ch1 data-start=\"226\" data-end=\"290\"\u003e\u003cstrong data-start=\"228\" data-end=\"290\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eRelè di protezione di fase TENSE - asimmetria regolabile 5-50\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp data-start=\"292\" data-end=\"616\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè di protezione di fase \u003cstrong data-start=\"328\" data-end=\"347\"\u003eTENSE (Turchia)\u003c\/strong\u003e è progettato per proteggere i motori elettrici trifase e altre apparecchiature trifase da guasti nella rete di alimentazione. Il dispositivo controlla la \u003cstrong data-start=\"477\" data-end=\"498\"\u003ecorretta sequenza delle fasi\u003c\/strong\u003e, l'\u003cstrong data-start=\"500\" data-end=\"518\"\u003easimmetria delle fasi\u003c\/strong\u003e, la \u003cstrong data-start=\"520\" data-end=\"531\"\u003esottotensione\u003c\/strong\u003e e la \u003cstrong data-start=\"533\" data-end=\"544\"\u003esovratensione\u003c\/strong\u003e e garantisce la disconnessione sicura del carico quando vengono superati i limiti impostati.\u003c\/font\u003e\u003c\/p\u003e\n\u003cp data-start=\"618\" data-end=\"777\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eL'ampia gamma di impostazioni rende il relè adatto alla maggior parte delle applicazioni industriali e commerciali, soprattutto quando è richiesta una protezione del motore precisa e stabile.\u003c\/font\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"784\" data-end=\"809\"\u003e\u003cstrong data-start=\"787\" data-end=\"809\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCaratteristiche principali\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul data-start=\"810\" data-end=\"1250\"\u003e\n\u003cli data-start=\"810\" data-end=\"872\"\u003e\n\u003cp data-start=\"812\" data-end=\"872\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"812\" data-end=\"835\"\u003eControllo della sequenza di fase\u003c\/strong\u003e - protezione contro il cablaggio errato.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"873\" data-end=\"914\"\u003e\n\u003cp data-start=\"875\" data-end=\"914\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"875\" data-end=\"913\"\u003eAsimmetria regolabile: 5% - 50%\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"915\" data-end=\"956\"\u003e\n\u003cp data-start=\"917\" data-end=\"956\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"917\" data-end=\"955\"\u003eSottotensione regolabile: 260-360 V CA\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"957\" data-end=\"998\"\u003e\n\u003cp data-start=\"959\" data-end=\"998\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"959\" data-end=\"997\"\u003eSovratensione regolabile: 400-480 V CA\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1055\"\u003e\n\u003cp data-start=\"1001\" data-end=\"1055\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1001\" data-end=\"1054\"\u003eTempo di ritardo dell'errore regolabile (Err In): 1-30 s\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1056\" data-end=\"1105\"\u003e\n\u003cp data-start=\"1058\" data-end=\"1105\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u003cstrong data-start=\"1058\" data-end=\"1104\"\u003eTempo di recupero regolabile (Err OUT): 1-30 s\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1106\" data-end=\"1159\"\u003e\n\u003cp data-start=\"1108\" data-end=\"1159\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIndicazione chiara sul \u003cstrong data-start=\"1130\" data-end=\"1158\"\u003edisplay a 3×3 segmenti\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1160\" data-end=\"1212\"\u003e\n\u003cp data-start=\"1162\" data-end=\"1212\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAlta precisione e risposta rapida ai guasti della rete.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1250\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1250\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMontaggio su \u003cstrong data-start=\"1236\" data-end=\"1249\"\u003eguida DIN\u003c\/strong\u003e standard.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"1257\" data-end=\"1281\"\u003e\u003cstrong data-start=\"1260\" data-end=\"1281\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePrincipi di funzionamento\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-start=\"1283\" data-end=\"1306\"\u003e\u003cstrong data-start=\"1287\" data-end=\"1306\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFunzionamento normale\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1307\" data-end=\"1372\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eQuando tutte le tensioni di fase rientrano nei limiti e la sequenza delle fasi è corretta:\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1373\" data-end=\"1407\"\u003e\n\u003cli data-start=\"1373\" data-end=\"1386\"\u003e\n\u003cp data-start=\"1375\" data-end=\"1386\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eil relè scatta,\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1387\" data-end=\"1407\"\u003e\n\u003cp data-start=\"1389\" data-end=\"1407\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eil LED \u003cstrong data-start=\"1393\" data-end=\"1400\"\u003eOUT\u003c\/strong\u003e si accende.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1414\" data-end=\"1447\"\u003e\u003cstrong data-start=\"1418\" data-end=\"1447\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eErrore di alta tensione (H)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1448\" data-end=\"1646\"\u003e\n\u003cli data-start=\"1448\" data-end=\"1530\"\u003e\n\u003cp data-start=\"1450\" data-end=\"1530\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSe la fase supera il limite impostato → il tempo di \u003cstrong data-start=\"1501\" data-end=\"1511\"\u003eErr In\u003c\/strong\u003e è in attesa, viene visualizzato \u003cstrong data-start=\"1524\" data-end=\"1529\"\u003eH\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1531\" data-end=\"1559\"\u003e\n\u003cp data-start=\"1533\" data-end=\"1559\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè si disattiva, OUT si spegne.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1646\"\u003e\n\u003cp data-start=\"1562\" data-end=\"1646\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eQuando 5 V scende sotto il valore impostato, \u003cstrong data-start=\"1614\" data-end=\"1625\"\u003eErr OUT\u003c\/strong\u003e inizia a funzionare, il relè si riaccende.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1653\" data-end=\"1685\"\u003e\u003cstrong data-start=\"1657\" data-end=\"1685\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eErrore di bassa tensione (L)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1686\" data-end=\"1845\"\u003e\n\u003cli data-start=\"1686\" data-end=\"1753\"\u003e\n\u003cp data-start=\"1688\" data-end=\"1753\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCaduta al di sotto del limite impostato → \u003cstrong data-start=\"1724\" data-end=\"1734\"\u003eErr In in\u003c\/strong\u003e attesa, viene visualizzato \u003cstrong data-start=\"1747\" data-end=\"1752\"\u003eL\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1754\" data-end=\"1770\"\u003e\n\u003cp data-start=\"1756\" data-end=\"1770\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè si spegne.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1771\" data-end=\"1845\"\u003e\n\u003cp data-start=\"1773\" data-end=\"1845\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eQuando la tensione sale di 5 V sopra la soglia → \u003cstrong data-start=\"1815\" data-end=\"1826\"\u003eErr OUT\u003c\/strong\u003e in attesa, il relè si attiva.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1852\" data-end=\"1880\"\u003e\u003cstrong data-start=\"1856\" data-end=\"1880\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAsimmetria di fase (Asy)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1881\" data-end=\"2093\"\u003e\n\u003cli data-start=\"1881\" data-end=\"2006\"\u003e\n\u003cp data-start=\"1883\" data-end=\"1948\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSe la differenza di tensione tra le fasi supera la soglia impostata (5-50%):\u003c\/font\u003e\u003c\/p\u003e\n\u003cul data-start=\"1951\" data-end=\"2006\"\u003e\n\u003cli data-start=\"1951\" data-end=\"2006\"\u003e\n\u003cp data-start=\"1953\" data-end=\"2006\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cstrong data-start=\"1983\" data-end=\"1990\"\u003eASy\u003c\/strong\u003e viene visualizzato dopo il tempo di \u003cstrong data-start=\"1961\" data-end=\"1971\"\u003eErr In\u003c\/strong\u003e, il relè si disattiva.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2007\" data-end=\"2093\"\u003e\n\u003cp data-start=\"2009\" data-end=\"2093\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eQuando l'asimmetria si riduce sotto (soglia impostata - 2%) → tempo di attesa \u003cstrong data-start=\"2066\" data-end=\"2077\"\u003eErr OUT\u003c\/strong\u003e, il relè si attiva.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"2100\" data-end=\"2130\"\u003e\u003cstrong data-start=\"2104\" data-end=\"2130\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eErrore di sequenza di fase (pHs)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2131\" data-end=\"2333\"\u003e\n\u003cli data-start=\"2131\" data-end=\"2204\"\u003e\n\u003cp data-start=\"2133\" data-end=\"2204\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eQuando si verifica un errore di sequenza di fase, il relè attende \u003cstrong data-start=\"2171\" data-end=\"2181\"\u003eErr In\u003c\/strong\u003e, quindi visualizza \u003cstrong data-start=\"2196\" data-end=\"2203\"\u003epHs\u003c\/strong\u003e.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2205\" data-end=\"2271\"\u003e\n\u003cp data-start=\"2207\" data-end=\"2271\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè si spegne e rimane spento fino al ripristino della sequenza corretta.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2272\" data-end=\"2333\"\u003e\n\u003cp data-start=\"2274\" data-end=\"2333\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDopo la correzione della sequenza di fase, si verifica \u003cstrong data-start=\"2305\" data-end=\"2316\"\u003eErr OUT\u003c\/strong\u003e e il relè si accende.\u003c\/font\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2335\" data-end=\"2338\"\u003e\n\u003ch2 data-start=\"2340\" data-end=\"2366\"\u003e\u003cstrong data-start=\"2343\" data-end=\"2366\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eParametri tecnici\u003c\/font\u003e\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\u003cdiv tabindex=\"-1\" class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\"\u003e\u003ctable data-start=\"2368\" data-end=\"2982\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2368\" data-end=\"2390\"\u003e\u003ctr data-start=\"2368\" data-end=\"2390\"\u003e\n\u003cth data-start=\"2368\" data-end=\"2379\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eParametro\u003c\/font\u003e\u003c\/th\u003e\n\u003cth data-start=\"2379\" data-end=\"2390\" data-col-size=\"sm\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eValore\u003c\/font\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody data-start=\"2413\" data-end=\"2982\"\u003e\n\u003ctr data-start=\"2413\" data-end=\"2458\"\u003e\n\u003ctd data-start=\"2413\" data-end=\"2440\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2415\" data-end=\"2439\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTensione di esercizio (Un)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2440\" data-end=\"2458\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e3×380 V CA + N\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2459\" data-end=\"2487\"\u003e\n\u003ctd data-start=\"2459\" data-end=\"2475\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2461\" data-end=\"2474\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eFrequenza\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2475\" data-end=\"2487\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e50\/60 Hz\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2488\" data-end=\"2511\"\u003e\n\u003ctd data-start=\"2488\" data-end=\"2501\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2490\" data-end=\"2500\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePotenza assorbita\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2501\" data-end=\"2511\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u0026lt; 6 VA\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2512\" data-end=\"2552\"\u003e\n\u003ctd data-start=\"2512\" data-end=\"2532\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2514\" data-end=\"2531\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTemperatura ambiente\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2532\" data-end=\"2552\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDa -20 °C a +55 °C\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2553\" data-end=\"2596\"\u003e\n\u003ctd data-start=\"2553\" data-end=\"2580\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2555\" data-end=\"2579\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSoglia di alta tensione\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2580\" data-end=\"2596\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e400-480 V AC\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2597\" data-end=\"2639\"\u003e\n\u003ctd data-start=\"2597\" data-end=\"2623\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2599\" data-end=\"2622\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSoglia di bassa tensione\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2623\" data-end=\"2639\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e260-360 V AC\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2640\" data-end=\"2681\"\u003e\n\u003ctd data-start=\"2640\" data-end=\"2656\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2642\" data-end=\"2655\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAsimmetria\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2656\" data-end=\"2681\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e5-50% (regolabile)\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2682\" data-end=\"2718\"\u003e\n\u003ctd data-start=\"2682\" data-end=\"2708\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2684\" data-end=\"2707\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTempo di errore (Err In)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2708\" data-end=\"2718\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e1-30 s\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2719\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2719\" data-end=\"2747\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2721\" data-end=\"2746\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eTempo di reset (Err OUT)\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2747\" data-end=\"2757\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e1-30 s\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2814\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2777\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2760\" data-end=\"2776\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eContatto relè\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2777\" data-end=\"2814\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e5 A \/ 250 V CA (carico resistivo)\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2815\" data-end=\"2852\"\u003e\n\u003ctd data-start=\"2815\" data-end=\"2829\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2817\" data-end=\"2828\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eDisplay\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2829\" data-end=\"2852\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e3×3 segmenti, 1 LED\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2853\" data-end=\"2879\"\u003e\n\u003ctd data-start=\"2853\" data-end=\"2866\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2855\" data-end=\"2865\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMontaggio\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2866\" data-end=\"2879\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eGuida DIN\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2880\" data-end=\"2906\"\u003e\n\u003ctd data-start=\"2880\" data-end=\"2895\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2882\" data-end=\"2894\"\u003e\u003cfont style=\"font-size: 14px;\"\u003ePeso\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2895\" data-end=\"2906\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u0026lt; 150 g\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2907\" data-end=\"2947\"\u003e\n\u003ctd data-start=\"2907\" data-end=\"2935\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2909\" data-end=\"2934\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAltezza massima di installazione\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2935\" data-end=\"2947\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e\u0026lt; 2000 m\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2948\" data-end=\"2982\"\u003e\n\u003ctd data-start=\"2948\" data-end=\"2968\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2950\" data-end=\"2967\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eSezione del cavo\u003c\/font\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2968\" data-end=\"2982\"\u003e\u003cfont style=\"font-size: 14px;\"\u003efino a 2,5 mm²\u003c\/font\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cul\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Default Title","offer_id":52989459726668,"sku":"FKV-03HF","price":35.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0941\/8391\/5852\/files\/832dc14996d8a591923779b140e90b0f.png?v=1753395107"},{"product_id":"rele-trifase-di-monitoraggio-protezione-per-sovratensione-sottotensione-controllo-di-sequenza-guasto","title":"Relè trifase di monitoraggio\/protezione per sovratensione, sottotensione, controllo di sequenza\/guasto","description":"\u003cp\u003e\u003cstrong\u003eRelè di controllo - relè di guardia\/protezione trifase per il controllo di sovratensione, sottotensione, slitta, mancanza di fase con timer. GKM-12\/12F (TENSIONE)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eI relè di protezione di fase sono progettati per proteggere i carichi trifase dai danni causati dalla tensione di linea.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\t\u003cli\u003eTensione: 230V - 300V AC (regolabile)\u003c\/li\u003e\t\u003cli\u003eSottotensione: 140V - 210V CA (regolabile)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eTimer: 0,1 s - 20 s (regolabile)\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eProtezione da guasti di fase\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003eControllo della sequenza di fase (GKM-12F)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eMontaggio su guida DIN\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eLarghezza 17,8 mm\u003c\/p\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Sì","offer_id":57032481898828,"sku":"GKV-12F","price":39.24,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":57032481931596,"sku":"GKV-12","price":40.12,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0941\/8391\/5852\/files\/file_bb5bc74d-7f86-4cdc-b28f-6b05dd516274.webp?v=1774001088"},{"product_id":"rele-trifase-di-monitoraggio-protezione-per-sovratensione-sottotensione-controllo-di-sequenza-guasto-1","title":"Relè trifase di monitoraggio\/protezione per sovratensione, sottotensione, controllo di sequenza\/guasto","description":"\u003cp\u003e\u003cstrong\u003eRelè trifase di monitoraggio\/protezione per il controllo di sovratensione, sottotensione, sequenza, mancanza di fase con timer. GKT-03\/03F (ECCITATO)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003eI relè di protezione di fase sono progettati per proteggere i carichi trifase dai danni causati dalla tensione di linea.\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\t\u003cli\u003eTensione: 400 V - 510 V CA (regolabile)\u003c\/li\u003e\t\u003cli\u003eSottotensione: 260 V - 370 V CA (regolabile)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eTimer: 0,1 s - 20 s (regolabile)\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eProtezione da guasti di fase\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003eControllo della sequenza di fase (GKT-03F)\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eMontaggio su guida DIN\u003c\/p\u003e\t\u003c\/li\u003e\t\u003cli\u003e\t\u003cp\u003eLarghezza 35,4 mm\u003c\/p\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Sì","offer_id":57032484651340,"sku":"GKT-03F","price":47.76,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":57032484684108,"sku":"GKT-03","price":49.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0941\/8391\/5852\/files\/file_707282c9-164e-4dcb-8b6a-306689a0f0ea.png?v=1774001154"},{"product_id":"rele-trifase-di-monitoraggio-protezione-per-sovratensione-sottotensione-controllo-di-sequenza-guasto-2","title":"Relè trifase di monitoraggio\/protezione per sovratensione, sottotensione, controllo di sequenza\/guasto","description":"\u003ch1 data-start=\"184\" data-end=\"249\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"186\" data-end=\"247\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eRelè trifase per il monitoraggio della tensione - GKM-02F (TENSE)\u003c\/font\u003e\u003c\/span\u003e\u003c\/h1\u003e\u003cp data-start=\"250\" data-end=\"351\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"250\" data-end=\"351\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoraggio di sovratensione\/sottotensione - Sequenza di fase - Controllo presenza zero - Uscita 5A - 140-300 VAC\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp data-start=\"353\" data-end=\"709\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè di monitoraggio trifase \u003cspan data-start=\"381\" data-end=\"392\" style=\"font-weight: 600;\"\u003eGKM-02F\u003c\/span\u003e di \u003cspan data-start=\"404\" data-end=\"413\" style=\"font-weight: 600;\"\u003eTENSE\u003c\/span\u003e è progettato per proteggere i carichi trifase da pericolose deviazioni di stato nella rete di alimentazione. Il dispositivo monitora la presenza di sottotensione, sovratensione, perdita di fase, sequenza di fase errata e guasto del conduttore di neutro.\u003cbr data-start=\"616\" data-end=\"619\"\u003eQuando viene rilevato un guasto, il relè scollega immediatamente il contatto di uscita, proteggendo le apparecchiature collegate.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"716\" data-end=\"741\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"719\" data-end=\"741\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCaratteristiche principali\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul data-start=\"743\" data-end=\"1789\"\u003e\n\u003cli data-start=\"743\" data-end=\"876\"\u003e\u003cp data-start=\"745\" data-end=\"876\"\u003e\u003cspan data-start=\"745\" data-end=\"772\" style=\"font-weight: 600;\"\u003eMonitoraggio delle sovratensioni (HV):\u003c\/span\u003e\u003cbr data-start=\"772\" data-end=\"775\"\u003e- Reagisce al superamento del livello impostato in qualsiasi fase\u003cbr data-start=\"835\" data-end=\"838\"\u003e- Campo di impostazione: \u003cspan data-start=\"860\" data-end=\"876\" style=\"font-weight: 600;\"\u003e230-300 VCA\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"878\" data-end=\"997\"\u003e\u003cp data-start=\"880\" data-end=\"997\"\u003e\u003cspan data-start=\"880\" data-end=\"907\" style=\"font-weight: 600;\"\u003eMonitoraggio della sottotensione (LV):\u003c\/span\u003e\u003cbr data-start=\"907\" data-end=\"910\"\u003e- Reagisce alla caduta di tensione in qualsiasi fase\u003cbr data-start=\"956\" data-end=\"959\"\u003e- Campo di impostazione: \u003cspan data-start=\"981\" data-end=\"997\" style=\"font-weight: 600;\"\u003e140-210 V CA\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1106\"\u003e\u003cp data-start=\"1001\" data-end=\"1106\"\u003e\u003cspan data-start=\"1001\" data-end=\"1035\" style=\"font-weight: 600;\"\u003eTempo di risposta regolabile (DT):\u003c\/span\u003e\u003cbr data-start=\"1035\" data-end=\"1038\"\u003e- Ritardo nella risposta a una condizione di guasto\u003cbr data-start=\"1075\" data-end=\"1078\"\u003e- intervallo: \u003cspan data-start=\"1090\" data-end=\"1106\" style=\"font-weight: 600;\"\u003e0,1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1228\"\u003e\u003cp data-start=\"1110\" data-end=\"1228\"\u003e\u003cspan data-start=\"1110\" data-end=\"1152\" style=\"font-weight: 600;\"\u003eReset automatico - tempo di ritorno (RT):\u003c\/span\u003e\u003cbr data-start=\"1152\" data-end=\"1155\"\u003e- Ritardo all'accensione dopo la normalizzazione della tensione\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e- intervallo: \u003cspan data-start=\"1212\" data-end=\"1228\" style=\"font-weight: 600;\"\u003e0,1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1355\"\u003e\u003cp data-start=\"1232\" data-end=\"1355\"\u003e\u003cspan data-start=\"1232\" data-end=\"1278\" style=\"font-weight: 600;\"\u003eMonitoraggio della sequenza di fase e della presenza di fase\u003c\/span\u003e\u003cbr data-start=\"1278\" data-end=\"1281\"\u003e- protezione contro una sequenza di fasi errata\u003cbr data-start=\"1328\" data-end=\"1331\"\u003e- Rilevamento dei guasti di fase\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1511\"\u003e\u003cp data-start=\"1359\" data-end=\"1511\"\u003e\u003cspan data-start=\"1359\" data-end=\"1407\" style=\"font-weight: 600;\"\u003eMonitoraggio della presenza del conduttore di neutro (N)\u003c\/span\u003e\u003cbr data-start=\"1407\" data-end=\"1410\"\u003e- Protezione contro la perdita del conduttore N nella rete\u003cbr data-start=\"1450\" data-end=\"1453\"\u003e- Disconnessione quando la tensione di alimentazione scende al di sotto di \u003cspan data-start=\"1500\" data-end=\"1511\" style=\"font-weight: 600;\"\u003e88 V CA\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1591\"\u003e\u003cp data-start=\"1515\" data-end=\"1591\"\u003e\u003cspan data-start=\"1515\" data-end=\"1532\" style=\"font-weight: 600;\"\u003eIsteresi 3%\u003c\/span\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003e- limita le commutazioni rapide indesiderate durante le fluttuazioni di tensione\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1593\" data-end=\"1660\"\u003e\u003cp data-start=\"1595\" data-end=\"1660\"\u003e\u003cspan data-start=\"1595\" data-end=\"1618\" style=\"font-weight: 600;\"\u003eSegnalazione ottica\u003c\/span\u003e\u003cbr data-start=\"1618\" data-end=\"1621\"\u003e- Indicatori LED per lo stato e il tipo di guasto\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1662\" data-end=\"1708\"\u003e\u003cp data-start=\"1664\" data-end=\"1708\"\u003e\u003cspan data-start=\"1664\" data-end=\"1708\" style=\"font-weight: 600;\"\u003eDesign compatto, montaggio su guida DIN\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1789\"\u003e\u003cp data-start=\"1712\" data-end=\"1789\"\u003e\u003cspan data-start=\"1712\" data-end=\"1733\" style=\"font-weight: 600;\"\u003eContatto di uscita:\u003c\/span\u003e\u003cbr data-start=\"1733\" data-end=\"1736\"\u003e- \u003cspan data-start=\"1740\" data-end=\"1751\" style=\"font-weight: 600;\"\u003eNO + NC\u003c\/span\u003e, contatto pulito\u003cbr data-start=\"1766\" data-end=\"1769\"\u003e- Carico di \u003cspan data-start=\"1782\" data-end=\"1789\" style=\"font-weight: 600;\"\u003e5 A\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1796\" data-end=\"1810\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1799\" data-end=\"1810\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplicazione\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"1812\" data-end=\"1859\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè è progettato per proteggere dispositivi quali:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1861\" data-end=\"1973\"\u003e\n\u003cli data-start=\"1861\" data-end=\"1881\"\u003e\u003cp data-start=\"1863\" data-end=\"1881\"\u003emotori trifase\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1882\" data-end=\"1896\"\u003e\u003cp data-start=\"1884\" data-end=\"1896\"\u003ecompressori\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1909\"\u003e\u003cp data-start=\"1899\" data-end=\"1909\"\u003epompe\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1935\"\u003e\u003cp data-start=\"1912\" data-end=\"1935\"\u003eunità di condizionamento dell'aria\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1936\" data-end=\"1973\"\u003e\u003cp data-start=\"1938\" data-end=\"1973\"\u003ecarichi industriali e domestici in generale\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1975\" data-end=\"1987\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtegge da:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1989\" data-end=\"2087\"\u003e\n\u003cli data-start=\"1989\" data-end=\"2001\"\u003e\u003cp data-start=\"1991\" data-end=\"2001\"\u003esovratensione\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2014\"\u003e\u003cp data-start=\"2004\" data-end=\"2014\"\u003esottotensione\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2032\"\u003e\u003cp data-start=\"2017\" data-end=\"2032\"\u003emancanza di fase\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2033\" data-end=\"2059\"\u003e\u003cp data-start=\"2035\" data-end=\"2059\"\u003esequenza di fase errata\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2087\"\u003e\u003cp data-start=\"2062\" data-end=\"2087\"\u003eperdita del conduttore di neutro\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2094\" data-end=\"2120\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"2097\" data-end=\"2120\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAVVISO IMPORTANTE\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"2122\" data-end=\"2267\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cspan data-start=\"2125\" data-end=\"2152\" style=\"font-weight: 600;\"\u003eIl relè NON regola la tensione!\u003c\/span\u003e\u003cbr data-start=\"2152\" data-end=\"2155\"\u003eServe solo a \u003cem data-start=\"2170\" data-end=\"2187\"\u003escollegare il carico\u003c\/em\u003e in caso di condizioni pericolose nella rete, non a stabilizzare o compensare la tensione.\u003c\/font\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Sì","offer_id":57032487895372,"sku":"GKM-02F","price":47.76,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":57032487960908,"sku":"GKM-02","price":49.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0941\/8391\/5852\/files\/file_99971656-efec-4c77-9c9a-f950671a92f8.webp?v=1774001199"}],"url":"https:\/\/prelek.it\/collections\/ochranne-rele-proti-prepeti-podpeti.oembed","provider":"PELEK_IT","version":"1.0","type":"link"}