{"product_id":"rele-trifase-di-monitoraggio-protezione-per-sovratensione-sottotensione-controllo-di-sequenza-guasto-2","title":"Relè trifase di monitoraggio\/protezione per sovratensione, sottotensione, controllo di sequenza\/guasto","description":"\u003ch1 data-start=\"184\" data-end=\"249\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"186\" data-end=\"247\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 18px;\"\u003eRelè trifase per il monitoraggio della tensione - GKM-02F (TENSE)\u003c\/font\u003e\u003c\/span\u003e\u003c\/h1\u003e\u003cp data-start=\"250\" data-end=\"351\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cspan data-start=\"250\" data-end=\"351\" style=\"font-weight: 600;\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eMonitoraggio di sovratensione\/sottotensione - Sequenza di fase - Controllo presenza zero - Uscita 5A - 140-300 VAC\u003c\/font\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp data-start=\"353\" data-end=\"709\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè di monitoraggio trifase \u003cspan data-start=\"381\" data-end=\"392\" style=\"font-weight: 600;\"\u003eGKM-02F\u003c\/span\u003e di \u003cspan data-start=\"404\" data-end=\"413\" style=\"font-weight: 600;\"\u003eTENSE\u003c\/span\u003e è progettato per proteggere i carichi trifase da pericolose deviazioni di stato nella rete di alimentazione. Il dispositivo monitora la presenza di sottotensione, sovratensione, perdita di fase, sequenza di fase errata e guasto del conduttore di neutro.\u003cbr data-start=\"616\" data-end=\"619\"\u003eQuando viene rilevato un guasto, il relè scollega immediatamente il contatto di uscita, proteggendo le apparecchiature collegate.\u003c\/font\u003e\u003c\/p\u003e\u003ch2 data-start=\"716\" data-end=\"741\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"719\" data-end=\"741\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eCaratteristiche principali\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cul data-start=\"743\" data-end=\"1789\"\u003e\n\u003cli data-start=\"743\" data-end=\"876\"\u003e\u003cp data-start=\"745\" data-end=\"876\"\u003e\u003cspan data-start=\"745\" data-end=\"772\" style=\"font-weight: 600;\"\u003eMonitoraggio delle sovratensioni (HV):\u003c\/span\u003e\u003cbr data-start=\"772\" data-end=\"775\"\u003e- Reagisce al superamento del livello impostato in qualsiasi fase\u003cbr data-start=\"835\" data-end=\"838\"\u003e- Campo di impostazione: \u003cspan data-start=\"860\" data-end=\"876\" style=\"font-weight: 600;\"\u003e230-300 VCA\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"878\" data-end=\"997\"\u003e\u003cp data-start=\"880\" data-end=\"997\"\u003e\u003cspan data-start=\"880\" data-end=\"907\" style=\"font-weight: 600;\"\u003eMonitoraggio della sottotensione (LV):\u003c\/span\u003e\u003cbr data-start=\"907\" data-end=\"910\"\u003e- Reagisce alla caduta di tensione in qualsiasi fase\u003cbr data-start=\"956\" data-end=\"959\"\u003e- Campo di impostazione: \u003cspan data-start=\"981\" data-end=\"997\" style=\"font-weight: 600;\"\u003e140-210 V CA\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"999\" data-end=\"1106\"\u003e\u003cp data-start=\"1001\" data-end=\"1106\"\u003e\u003cspan data-start=\"1001\" data-end=\"1035\" style=\"font-weight: 600;\"\u003eTempo di risposta regolabile (DT):\u003c\/span\u003e\u003cbr data-start=\"1035\" data-end=\"1038\"\u003e- Ritardo nella risposta a una condizione di guasto\u003cbr data-start=\"1075\" data-end=\"1078\"\u003e- intervallo: \u003cspan data-start=\"1090\" data-end=\"1106\" style=\"font-weight: 600;\"\u003e0,1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1108\" data-end=\"1228\"\u003e\u003cp data-start=\"1110\" data-end=\"1228\"\u003e\u003cspan data-start=\"1110\" data-end=\"1152\" style=\"font-weight: 600;\"\u003eReset automatico - tempo di ritorno (RT):\u003c\/span\u003e\u003cbr data-start=\"1152\" data-end=\"1155\"\u003e- Ritardo all'accensione dopo la normalizzazione della tensione\u003cbr data-start=\"1197\" data-end=\"1200\"\u003e- intervallo: \u003cspan data-start=\"1212\" data-end=\"1228\" style=\"font-weight: 600;\"\u003e0,1 s - 20 s\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1355\"\u003e\u003cp data-start=\"1232\" data-end=\"1355\"\u003e\u003cspan data-start=\"1232\" data-end=\"1278\" style=\"font-weight: 600;\"\u003eMonitoraggio della sequenza di fase e della presenza di fase\u003c\/span\u003e\u003cbr data-start=\"1278\" data-end=\"1281\"\u003e- protezione contro una sequenza di fasi errata\u003cbr data-start=\"1328\" data-end=\"1331\"\u003e- Rilevamento dei guasti di fase\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1357\" data-end=\"1511\"\u003e\u003cp data-start=\"1359\" data-end=\"1511\"\u003e\u003cspan data-start=\"1359\" data-end=\"1407\" style=\"font-weight: 600;\"\u003eMonitoraggio della presenza del conduttore di neutro (N)\u003c\/span\u003e\u003cbr data-start=\"1407\" data-end=\"1410\"\u003e- Protezione contro la perdita del conduttore N nella rete\u003cbr data-start=\"1450\" data-end=\"1453\"\u003e- Disconnessione quando la tensione di alimentazione scende al di sotto di \u003cspan data-start=\"1500\" data-end=\"1511\" style=\"font-weight: 600;\"\u003e88 V CA\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1513\" data-end=\"1591\"\u003e\u003cp data-start=\"1515\" data-end=\"1591\"\u003e\u003cspan data-start=\"1515\" data-end=\"1532\" style=\"font-weight: 600;\"\u003eIsteresi 3%\u003c\/span\u003e\u003cbr data-start=\"1532\" data-end=\"1535\"\u003e- limita le commutazioni rapide indesiderate durante le fluttuazioni di tensione\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1593\" data-end=\"1660\"\u003e\u003cp data-start=\"1595\" data-end=\"1660\"\u003e\u003cspan data-start=\"1595\" data-end=\"1618\" style=\"font-weight: 600;\"\u003eSegnalazione ottica\u003c\/span\u003e\u003cbr data-start=\"1618\" data-end=\"1621\"\u003e- Indicatori LED per lo stato e il tipo di guasto\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1662\" data-end=\"1708\"\u003e\u003cp data-start=\"1664\" data-end=\"1708\"\u003e\u003cspan data-start=\"1664\" data-end=\"1708\" style=\"font-weight: 600;\"\u003eDesign compatto, montaggio su guida DIN\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1710\" data-end=\"1789\"\u003e\u003cp data-start=\"1712\" data-end=\"1789\"\u003e\u003cspan data-start=\"1712\" data-end=\"1733\" style=\"font-weight: 600;\"\u003eContatto di uscita:\u003c\/span\u003e\u003cbr data-start=\"1733\" data-end=\"1736\"\u003e- \u003cspan data-start=\"1740\" data-end=\"1751\" style=\"font-weight: 600;\"\u003eNO + NC\u003c\/span\u003e, contatto pulito\u003cbr data-start=\"1766\" data-end=\"1769\"\u003e- Carico di \u003cspan data-start=\"1782\" data-end=\"1789\" style=\"font-weight: 600;\"\u003e5 A\u003c\/span\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"1796\" data-end=\"1810\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"1799\" data-end=\"1810\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eApplicazione\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"1812\" data-end=\"1859\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eIl relè è progettato per proteggere dispositivi quali:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1861\" data-end=\"1973\"\u003e\n\u003cli data-start=\"1861\" data-end=\"1881\"\u003e\u003cp data-start=\"1863\" data-end=\"1881\"\u003emotori trifase\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1882\" data-end=\"1896\"\u003e\u003cp data-start=\"1884\" data-end=\"1896\"\u003ecompressori\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1897\" data-end=\"1909\"\u003e\u003cp data-start=\"1899\" data-end=\"1909\"\u003epompe\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1910\" data-end=\"1935\"\u003e\u003cp data-start=\"1912\" data-end=\"1935\"\u003eunità di condizionamento dell'aria\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"1936\" data-end=\"1973\"\u003e\u003cp data-start=\"1938\" data-end=\"1973\"\u003ecarichi industriali e domestici in generale\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp data-start=\"1975\" data-end=\"1987\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eProtegge da:\u003c\/font\u003e\u003c\/p\u003e\u003cul data-start=\"1989\" data-end=\"2087\"\u003e\n\u003cli data-start=\"1989\" data-end=\"2001\"\u003e\u003cp data-start=\"1991\" data-end=\"2001\"\u003esovratensione\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2002\" data-end=\"2014\"\u003e\u003cp data-start=\"2004\" data-end=\"2014\"\u003esottotensione\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2015\" data-end=\"2032\"\u003e\u003cp data-start=\"2017\" data-end=\"2032\"\u003emancanza di fase\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2033\" data-end=\"2059\"\u003e\u003cp data-start=\"2035\" data-end=\"2059\"\u003esequenza di fase errata\u003c\/p\u003e\u003c\/li\u003e\n\u003cli data-start=\"2060\" data-end=\"2087\"\u003e\u003cp data-start=\"2062\" data-end=\"2087\"\u003eperdita del conduttore di neutro\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 data-start=\"2094\" data-end=\"2120\" style=\"font-family: \" open sans neue helvetica arial sans-serif rgb color:=\"\"\u003e\u003cspan data-start=\"2097\" data-end=\"2120\"\u003e\u003cfont style=\"font-size: 14px;\"\u003eAVVISO IMPORTANTE\u003c\/font\u003e\u003c\/span\u003e\u003c\/h2\u003e\u003cp data-start=\"2122\" data-end=\"2267\" style=\"color: rgb(78, 86, 95);\"\u003e\u003cfont style=\"font-size: 14px;\"\u003e \u003cspan data-start=\"2125\" data-end=\"2152\" style=\"font-weight: 600;\"\u003eIl relè NON regola la tensione!\u003c\/span\u003e\u003cbr data-start=\"2152\" data-end=\"2155\"\u003eServe solo a \u003cem data-start=\"2170\" data-end=\"2187\"\u003escollegare il carico\u003c\/em\u003e in caso di condizioni pericolose nella rete, non a stabilizzare o compensare la tensione.\u003c\/font\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\t\u003cp\u003e\u003c\/p\u003e\t\u003cbr\u003e\t\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003c\/p\u003e","brand":"TENSE","offers":[{"title":"Sì","offer_id":57032487895372,"sku":"GKM-02F","price":47.76,"currency_code":"EUR","in_stock":false},{"title":"No","offer_id":57032487960908,"sku":"GKM-02","price":49.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0941\/8391\/5852\/files\/file_99971656-efec-4c77-9c9a-f950671a92f8.webp?v=1774001199","url":"https:\/\/prelek.it\/products\/rele-trifase-di-monitoraggio-protezione-per-sovratensione-sottotensione-controllo-di-sequenza-guasto-2","provider":"PELEK_IT","version":"1.0","type":"link"}